Administration Status Change Alarm

acgwAdminStateChange

Alarm

acgwAdminStateChange

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.7

Description

The alarm is sent when Graceful Shutdown commences and ends.

Default Severity

Major

Source Varbind Text

Board#1

Event Type

processingErrorAlarm

Probable Cause

outOfService (71)

Severity

Condition

Text

Corrective Action

Major

Admin state changed to shutting down

"Network element admin state change alarm: Device is shutting down.  No time limit."

No corrective action is required.
A network administrator took an action to gracefully lock the device.

Major

Admin state changed to locked

"Network element admin state change alarm. Device is Locked"

No corrective action is required.
A network administrator took an action to lock the device, or a graceful lock timeout occurred.

Cleared

Admin state changed to unlocked

-

No corrective action is required.
A network administrator has taken an action to unlock the device.